Bibliography





Notice:

  • Clicking on the title will open a new window with all details of the bibliographic entry.
  • Clicking on the DOI link will open a new window with the original bibliographic entry from the publisher.
  • Clicking on a single author will show all publications by the selected author.
  • Clicking on a single keyword, will show all publications by the selected keyword.



Found 5 entries in the Bibliography.


Showing entries from 1 through 5


2014

RadFET Dosimeters in the Belt: the Van Allen Probes on Day 365

Van Allen Probes A and B, launched more than a year ago (in August 2012), carried 16 p-channel metal-oxide-semiconductor Radiation-sensitive Field Effect Transistors (RadFET)s into an orbit designed by NASA to probe the heart of the trapped-radiation belts. Nearly 350 days of in situ measurements from the Engineering Radiation Monitor (ERM) (1) demonstrated strong variations of dose rates with time, (2) revealed a critical correlation between the ERM RadFET dosimeters and the ERM Faraday cup data on charged particles, and (3) permitted the mapping of the belts by measuring variation with orbit altitude. This paper provides an update on early results given in a NSREC2012 paper along with details and discussion of the RadFET dosimetry data analyzed .

Holmes-Siedle, A.G.; Maurer, R.; Peplowski, P.;

Published by: IEEE Transactions on Nuclear Science      Published on: 04/2014

YEAR: 2014     DOI:

RadFET Dosimeters in the Belt: the Van Allen Probes on Day 365

Van Allen Probes A and B, launched more than a year ago (in August 2012), carried 16 p-channel metal-oxide-semiconductor Radiation-sensitive Field Effect Transistors (RadFET)s into an orbit designed by NASA to probe the heart of the trapped-radiation belts. Nearly 350 days of in situ measurements from the Engineering Radiation Monitor (ERM) (1) demonstrated strong variations of dose rates with time, (2) revealed a critical correlation between the ERM RadFET dosimeters and the ERM Faraday cup data on charged particles, and (3) permitted the mapping of the belts by measuring variation with orbit altitude. This paper provides an update on early results given in a NSREC2012 paper along with details and discussion of the RadFET dosimetry data analyzed .

Holmes-Siedle, A.; Goldsten, J.; Maurer, R.; Peplowski, P.;

Published by: IEEE Transactions on Nuclear Science      Published on: 04/2014

YEAR: 2014     DOI: 10.1109/TNS.2014.2307012

Van Allen Probes

2013

Early Results From the Engineering Radiation Monitor (ERM) and Solar Cell Monitor on the Van Allen Probes Mission

The Engineering Radiation Monitor (ERM) measures dose, dose rate and charging currents on the Van Allen Probes mission to study the dynamics of earth\textquoterights Van Allen radiation belts. Early results from this monitor show a variation in dose rates with time, a correlation between the dosimeter and charging current data, a map of charging current versus orbit altitude and a comparison of cumulative dose to pre-launch modeling after 260 days. Solar cell degradation monitor patches track the decrease in solar array output as displacement damage accumulates.

Maurer, Richard; Goldsten, John; Peplowski, Patrick; Holmes-Siedle, Andrew; Butler, Michael; Herrmann, Carl; Mauk, Barry;

Published by: IEEE Transactions on Nuclear Science      Published on: Jan-12-2013

YEAR: 2013     DOI: 10.1109/TNS.2013.2281937

Early Results from the Engineering Radiation Monitor (ERM) and Solar Cell Monitor on the Van Allen Probes Mission

The Engineering Radiation Monitor (ERM) measures dose, dose rate and charging currents on the Van Allen Probes mission to study the dynamics of earth\textquoterights Van Allen radiation belts. Early results from this monitor show a variation in dose rates with time, a correlation between the dosimeter and charging current data, a map of charging current versus orbit altitude and a comparison of cumulative dose to pre-launch modeling after 260 days. Solar cell degradation monitor patches track the decrease in solar array output as displacement damage accumulates.

Maurer, Richard; Goldsten, J.; Peplowski, P.; Holmes-Siedle, A.; Butler, Michael; Herrmann, C.; Mauk, B.;

Published by:       Published on: 11/2013

YEAR: 2013     DOI: 10.1109/TNS.2013.2281937

RBSP; Van Allen Probes

The Engineering Radiation Monitor for the Radiation Belt Storm Probes Mission

An Engineering Radiation Monitor (ERM) has been developed as a supplementary spacecraft subsystem for NASA\textquoterights Radiation Belt Storm Probes (RBSP) mission. The ERM will monitor total dose and deep dielectric charging at each RBSP spacecraft in real time. Configured to take the place of spacecraft balance mass, the ERM contains an array of eight dosimeters and two buried conductive plates. The dosimeters are mounted under covers of varying shielding thickness to obtain a dose-depth curve and characterize the electron and proton contributions to total dose. A 3-min readout cadence coupled with an initial sensitivity of \~0.01 krad should enable dynamic measurements of dose rate throughout the 9-hr RBSP orbit. The dosimeters are Radiation-sensing Field Effect Transistors (RadFETs) and operate at zero bias to preserve their response even when powered off. The range of the RadFETs extends above 1000 krad to avoid saturation over the expected duration of the mission. Two large-area (\~10 cm2) charge monitor plates set behind different thickness covers will measure the dynamic currents of weakly-penetrating electrons that can be potentially hazardous to sensitive electronic components within the spacecraft. The charge monitors can handle large events without saturating (\~3000 fA/cm2) and provide sufficient sensitivity (\~0.1 fA/cm2) to gauge quiescent conditions. High time-resolution (5 s) monitoring allows detection of rapid changes in flux and enables correlation of spacecraft anomalies with local space weather conditions. Although primarily intended as an engineering subsystem to monitor spacecraft radiation levels, real-time data from the ERM may also prove useful or interesting to a larger community.

Goldsten, J.; Maurer, R.; Peplowski, P.; Holmes-Siedle, A.; Herrmann, C.; Mauk, B.;

Published by: Space Science Reviews      Published on: 11/2013

YEAR: 2013     DOI: 10.1007/s11214-012-9917-x

RBSP; Van Allen Probes



  1